Page 109 - Westwood Heating Products

Westwood
1-800-442-1630
Please order by
No.
P
W
T11
rev. 1-1-09
No.
T60
P
W
T60
T70
T80
No.
P
W
Description
Standard 10,000 volt oil burner ignition transformer tester
Cad cell primary control and flame detector eye tester
"
AMP-MASTER" thermostat heat anticipator meter
Test standard iron core 10,000 volt oil burner ignition transformers
quickly and safely with this rugged, easy-to-use tester. All testing
is done from the primary side of the transformer avoiding contact
with the high voltage terminals. Tests transformer while mounted
right on the burner.
(
Note: Not for testing solid state igniters)
Safely tests from the transformer's primary side
Transformer remains on the burner for testing
Detects early stages of transformer breakdown
Easy access built-in fuse protects meter
Simple, easy-to-read meter
Plugs into 120 volt outlet (ie. trouble light)
"
Service Truck Tough" with high impact case
Westwood
OIL BURNER IGNITION TRANSFORMER TESTER
No.
T70
P
W
Test both cad cell primary control and flame detector eye
simultaneously without removing components from the burner.
Built-in flame simulators for all popular controls insure accurate
diagnosis and testing.
Westwood
CAD CELL RELAY & EYE TESTER
Tests primary control and eye right on the burner
Simple, easy-to-read and understand ohmmeter
Built-in flame simulators for all popular controls
"
Service Truck Tough" with high impact case
No.
T80
P
W
Precisely measures the thermostat control circuit current to allow
correct setting of the heat anticipator. Avoids repeat service calls
to remedy short cycling or override problems. Connects at either
the thermostat or relay.
Westwood
"
AMP-MASTER" THERMOSTAT CIRCUIT METER
Accurately measures thermostat control circuit
draw to correctly adjust heat anticipator setting
Meter dial matches T87F heat anticipator scale
"
Service Truck Tough" with high impact case