Page 15 - RS-Electrical_web

Contact: RectorSeal
®
713-263-8001 800-231-3345 713-263-7577 800-441-0051
P
F
W
15
Wire Pulling Devices
Firestopping
Pipe Joining
Other Products
Wire Pulling Tools
Wire Pulli
g Devices
WI RE SNAGGER
®
SPEC I F I CAT I ONS FOR THHN & XHHW COPPER WI RE
Wire
Snagger
®
Wire Size
Max
Intermittent
Load (lbs)
Max
Continuous
Load (lbs)
Min
conductor
dia. (in)
Max
conductor
dia. (in)
Max
overall
dia. (in)
Minimum
EMT Conduit Size (in)
One
Tool
Five
Tools
One
Tool
Five
Tools
1
Wire 2 Wires 3 Wires 4 Wires 5 Wires
WS 3/0
2/0
1000 5000
600
3000
0.376
0.470
0.590
1-½ 2
2
2*
2-½
3/0
1000 5000
600
3000
1-½ 2
2*
2*
2-½
WS 4/0
4/0
1600 8000 1000 5000
0.475
0.575
0.720
2
2-½ 2-½ 2-½ 2-½*
250
MCM 2400 12000 1400 7000
2
2-½ 2 -½ 2 -½ 2 -½*
WS 350 350 MCM 2400 12000 1400 7000
0.616
0.681
0.825
2
2-½ 2-½ 2-½ 3
WS 500 500 MCM 3600 18000 2200 11000
0.736
0.813
0.960
2-½ 3
3
3*
3-½
WS 600 600 MCM 3600 18000 2200 11000
0.813
0.893
1.080
2 -½ 3
3*
3-½ 4
WS 750 750 MCM 3600 18000 2200 11000
0.908
0.998
1.156
2-½ 3*
3-½ 4
-
For use on THHN & XHHN copper wire only.
*
May require special service (such as removing bushing and installing extra guide pulleys) when pulling Max diameter wires through Min size conduit.
WI RE SNAGGER
®
SPEC I F I CAT I ONS FOR THHN & XHHW ALUM I NUM BU I LD I NG WI RE
Wire
Snagger
®
Wire Size
Max
Number
Strands¹
Max
Intermittent
Load (lbs)
Max
Continuous
Load (lbs)
Min
conductor
dia. (in)
Max
conductor
dia. (in)
Min
insulation
dia. (in)
Max
insulation
dia. (in)
Minimum
EMT Conduit Size (in)
One
Tool
Four
Tools
One
Tool
Four
Tools
1
Wire
2
Wires
3
Wires
4
Wires
WS 3/0
2/0
12
800 3200 600 2400
0.379
0.461
0.489
0.589
1-½ 2
2
2
3/0
18
900 3600 700 2800
1-½ 2
2
2
3/0
(
E194343)²
19
550 2200 400 1600
1-½ 2
2
2
4/0
(
Simpull)
19
1000 4000 750 3000
2 2-½ 2-½ 2-½
WS 4/0
4/0
19
1000 4000 750 3000
0.461
0.520
0.589
0.655
2 2-½ 2-½ 2-½
250
MCM 23
1000 4000 750 3000
2 2-½ 2-½ 2-½
250
MCM 35
900 3600 650 2600
2 2-½ 2-½ 2-½
WS 350
350
MCM 35
2000 8000 1400 5600
0.600
0.659
0.746
0.789
2 2-½ 2-½ 2-½
350
MCM 37
1600 6400 1200 4800
2 2-½ 2-½ 2-½
400
MCM 35
2600 10400 1900 7600
2 2-½ 2-½ 2-½
WS 500
500
MCM
(
E194343)²
35
1400 5600 1000 4000
0.720
0.795
0.866
0.971
2-½ 3
3
3
500
MCM 37
3000 12000 2200 8800
2-½ 3
3
3
600
MCM
(
Simpull)
41
3300 13200 2200 8800
2-½ 3
3
3
WS 600
600
MCM 61
2600 10400 1900 7600
0.813
0.911
0.973
1.071
2-½ 3
3 3-½
750
MCM 58
2800 11200 2100 8400
2-½ 3
3 3-½
WS 750 900 MCM -
-
-
-
-
0.963
1.002
1.139
1.162
3 3-½ 4
4
Notes:
1.
Pulling loads for any given wire size decreases as the number of strands increase.
2.
Pulling loads vary according to material properties.
3.
Contact RectorSeal for wire configurations different from those depicted in this table.
WI RE SNAGGER
®
LOAD CHART